CONTEC ECG Simulator Multi-Parameter ECG Patient Simulator MS400


Packing:Individual Pack

Dimension:18.86 cm(L)×12.50 cm(W)×4.32 cm(H)

Weigh: about 1.4kg

Accessaries:Standard accessories 9V/1A(CE) power adapter, an User manual, a packaging box, a plastic packaging.

 

                        CONTEC ECG Simulator Multi-Parameter MS400

 

MS400 Multiparameter Simulator is a portable device, features in small volume and light weight.

It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP.

And it can be tested in where the monitor is used.

 

  • Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and

pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non

Capture, Non Function).

  • Simulate four-channel IBP data.
  • Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three

kinds of apnea data.

  • Simulate four kinds of temperature data.
  • Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
  • Simulate standard ECG calibration, adult and pediatric ECG signal.
  • ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG

database and user-defined waveform data stored in TF card can be displayed by the simulator and exported

to the equipments to be tested.

  • Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.
  • Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
  • Optional operation modes: keys and touch screen.

Parameters:

ECG
Conventional: All leads have the same voltage with the II-lead as the reference
Amplitude: 0.5,1.0,1.5 and 2.0mV
ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180

200,220,240,260,280,300,320,340 and 350 BPM

ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV

 

Arrhythmia
Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block

 

Four IBP Channels
The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1:

Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right Ventricle: 25/00
Channel 2:

Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right Atrium(CVP): 15/10
Right Ventricle: 25/00
Pulmonary Artery: 25/10
Pulmonary Wedge: 10/2
Left Atrium: 14/4
Channel 3:

Artery: 120/80
Radial: 120/80
Left Ventricle: 120/00
Right Atrium(CVP): 15/10
Right Ventricle: 25/00
Pulmonary Artery: 25/10
Pulmonary Wedge: 10/2
Left Atrium: 14/4
Channel 4:
Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz: press ENTER key to change every time
Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3

 

Respiration
Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
Baseline impedance: 500, 1000, 1500, 2000Ω
Apnea: 12 s, 22 s, 32 s

 

Temperature
Four temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)